Unit 4, 12 Newtown Street, Bromley, Christchurch · Mon–Fri 8am–4.30pm Breakdown line answered 24/7 · 03 384 3374
  1. Home
  2. Water chillers

Water chillers, serviced, repaired and installed.

Process water, glycol and brine chillers sit at the heart of production and building cooling. When one goes down, everything downstream warms up. We keep them running.

In short

Southfreeze services, repairs and installs water, glycol and brine chillers for process and commercial use in Christchurch and Canterbury, with planned maintenance to keep them efficient and a 24/7 breakdown line when they fail.

  • Process & HVAC chillers
  • Glycol & brine
  • Planned maintenance
  • 24/7 breakdowns
Technician inspecting rooftop chiller and condensing plant
Chilled water+6.0°C

Water chiller enquiry

Breakdown right now? Call 03 384 3374, answered 24/7.

When

After-Hours Emergency Callout Fee: $350 + GST (includes travel, vehicle fee, and the first hour of service on-site). Urgent? Call 03 384 3374, answered 24/7.

How they work

A refrigeration system that cools water.

A chiller's evaporator takes heat out of water or glycol, which is pumped to wherever cooling is needed: jacketed tanks, heat exchangers, moulds, air handling units. The heat is rejected through an air-cooled condenser or a cooling tower. Every part of that loop has to be right for the chiller to hold its set point.

  • Chilled water, glycol and brine chillers
  • Air-cooled and water-cooled condensers
  • Cooling towers and heat recovery
  • Variable speed drives on compressors, fans and pumps
Condenserrejects heat outside Expansion valve Chilled water evaporatortakes heat out of the water Compressorpumps the refrigerant low-pressure vapourhigh-pressure liquid
Warning signs

Signs your chiller needs a look.

Leaving water too warmThe chiller can't hold its set point under load.
Short cyclingStarting and stopping constantly, wearing out the compressor.
High or low pressure tripsOften a condenser, flow or refrigerant charge problem.
Low flow or glycol issuesBlocked strainers, pump faults or weak glycol mix.
Fouled condenserDirty coils or tower water drive running costs up.
Noise and vibrationBearings, fans and compressors give early warnings.
FAQ

Common questions

How often should a water chiller be serviced?

It depends on duty and environment. Most process chillers benefit from regular inspections through the year, with condenser cleaning and water or glycol checks before the summer peak.

Do you work on glycol and brine chillers?

Yes. We service and repair water, glycol and brine chillers for process and commercial applications.

Can you improve an old chiller's efficiency?

Often. Clean condensers, correct refrigerant charge, good water treatment and variable speed drives on fans, pumps or compressors can all reduce running costs.

Fridge down? We're on the phone 24/7.

Christchurch commercial refrigeration since 1981. Call the breakdown line any time.

Call 03 384 3374 Get a quote